Document Type : Research article

Authors

1 Master's Student, Natural Resources-Environmental Engineering, Department of Environmental Sciences, Kheradgarayan Motahar Institute of Higher Education, Mashhad, Iran.

2 Assistant professor of Department of Environmental Sciences, Kheradgarayan Motahar Institute of Higher Education, Mashhad, Iran.

3 Assistant professor of Department of Environmental Sciences, Kheradgarayan Motahar Institute of Higher Education, Mashhad, Iran

Abstract

Background and Purpose: Poultry production is crucial in the global food supply chain. However, despite its economic benefits, the industry poses significant environmental challenges, notably air pollution. This study aims to evaluate air pollution in poultry farms throughout a growth cycle using statistical techniques and assess the effectiveness of a hybrid bipolar ionization system in mitigating air pollutants in this sector.

Materials and Methods: This research was carried out at an experimental poultry farm equipped with a hybrid bipolar ionization system to reduce particulate matter (PM), ammonia (NH₃), hydrogen sulfide (H₂S), and airborne microorganisms. The study examined the effects of three factors—negative ion concentration, humidity, and ventilation—at two levels, with two replications. The data were analyzed using SPSS and MSTAT-C software, employing analysis of variance (ANOVA) and the Kruskal-Wallis test at significance levels of 1%, 5%, and 10%.

Results: The results revealed that the most substantial reduction in particulate matter was achieved in Treatment 3 (low humidity, high ion concentration, and ventilation off), with reductions of 40.88% for PM₂.₅ and 31.91% for PM₁₀, at confidence levels of 90%, 95%, and 99%. The highest reduction in ammonia levels was also observed in Treatment 3, with a mean rank of 50.13. Complete elimination of hydrogen sulfide was observed in Treatment 4 (high ion concentration, low humidity, and ventilation on), with a mean rank of 50.14 at the 10% significance level. Maximum reduction of microorganisms occurred on day 3, with an ionization level of 7 kV, ventilation off, and 30% humidity (Treatment 3).

Conclusion: The study confirms that increasing the concentration of negative ions generated by the ionization system significantly reduces the concentration of airborne pollutants in poultry farms. Therefore, implementing a hybrid bipolar ionization system is recommended to enhance air quality in poultry houses.
 
Open Access Policy: This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/

Keywords

  1. Aghajani, S.M., et al., Molecular identification of wild strains of avian infectious bronchitis virus in vaccinated broiler flocks in Mazandaran province. 1398.
  2. Alonso, C., et al., Evaluation of an electrostatic particle ionization technology for decreasing airborne pathogens in pigs. Aerobiologia, 2016. 32: p. 405-419. https://doi.org/10.1007/s10453-015-9413-3 PMCid:PMC4996881
  3. Ariyai, N., M. Fathi Najafi, and Z. Saber, Different biological responses of neural progenitor cells to various collagen treatments in culture medium, in National Congress on Biology and Applied Aspects of Stem Cells. 1390.
  4. Arzbaecher, C.E. and P. Hurtado. Indoor Air Purification Technologies that Allow Reduced Outdoor Air Intake Rates While Maintaining Acceptable Levels of Indoor Air Quality. 2008.
  5. Bist, R.B., et al., Ammonia emissions, impacts, and mitigation strategies for poultry production: A critical review. Journal of Environmental Management, 2023. 328: p. 116919. https://doi.org/10.1016/j.jenvman.2022.116919 PMid:36516703
  6. Brouček, J., Methods of methane measurement in ruminants. Slovak Journal of Animal Science, 2014. 47(1): p. 51-60.
  7. Brouček, J. and B. Čermák, Emission of harmful gases from poultry farms and possibilities of their reduction. Ekológia (Bratislava), 2015. 34(1): p. 89-100. https://doi.org/10.1515/eko-2015-0010
  8. Daniels, S.L., On the qualities of the air as affected by radiant energies (photocatalytic ionization processes for remediation of indoor environments). Journal of environmental engineering and science, 2007. 6(3): p. 329-342. https://doi.org/10.1139/s06-072
  9. Daryadel, S., Environmental legal aspects of the poultry industry. 1395, University of law, Shahid Beheshti University, Tehran.
  10. Ensafi, A., Effects of air ionization in poultry houses on air and litter quality, performance, and immune responses of broiler chickens. 1395, Ministry of Science, Research, and Technology - University of Zanjan.
  11. Fazaeli rad, A.r., S.j. Modaresi, and F. Khosravi, Using negative air ionization systems to reduce Bacillus anthracis bacteria and spores in closed poultry systems, in National Conference on Passive Defense in the Agricultural Sector. 1392.
  12. Fojlaley, M., et al. Design and Evaluation of Air Ionizer with Plasam System and its Applications. 2015.
  13. Grinshpun, S., et al., Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces. Indoor air, 2005. 15(4): p. 235-245. https://doi.org/10.1111/j.1600-0668.2005.00364.x PMid:15982270
  14. Jerez, S., et al., Evaluation of Electrostatic Particle Ionization and BioCurtain Technologies to Reduce Dust, Odor and other Pollutants from Broiler Houses Final Report. 2011, Texas Water Resources Institute.
  15. Lin, X., et al., Emissions of ammonia, carbon dioxide and particulate matter from cage-free layer houses in California. Atmospheric Environment, 2017. 152: p. 246-255.
    https://doi.org/10.1016/j.atmosenv.2016.12.018
  16. Paknejad, S., et al., Measuring ammonia concentration in a poultry house and simulating the effect of ammonia on the production of Nox pollutants resulting from the combustion of jet heaters inside the poultry house, in The Third International Conference on Science and Engineering. 1395.
  17. Pushpawela, B., et al., Efficiency of ionizers in removing airborne particles in indoor environments. Journal of Electrostatics, 2017. 90: p. 79-84. https://doi.org/10.1016/j.elstat.2017.10.002
  18. Qian, C., Air ionizers case study. Journal of Physics: Conference Series, 2021. 2029(1): p. 012026. https://doi.org/10.1088/1742-6596/2029/1/012026
  19. Seyed abadi, H.r., S.a. Hosseini, and M. Ahmadi, Investigating the effect of management factors on the performance of broiler farms in Golestan Province using a multi-criteria decision-making system. Animal husbandry sciences and techniques, 2015. 4(16): p. 3-10.
  20. Shepherd, T.A., et al., Environmental assessment of three egg production systems-Part II. Ammonia, greenhouse gas, and particulate matter emissions. Poultry science, 2015. 94(3): p. 534-543. https://doi.org/10.3382/ps/peu075 PMid:25737568 PMCid:PMC4990889
  21. Shiue, A., S.-C. Hu, and M.-L. Tu, Particles removal by negative ionic air purifier in cleanroom. Aerosol and Air Quality Research, 2011. 11(2): p. 179-186. https://doi.org/10.4209/aaqr.2010.06.0048
  22. Winkel, A., et al., Evaluation of oil spraying systems and air ionisation systems for abatement of particulate matter emission in commercial poultry houses. Biosystems Engineering, 2016. 150: p. 104-122. https://doi.org/10.1016/j.biosystemseng.2016.07.014
  23. Winkel, A., et al., Emissions of particulate matter from animal houses in the Netherlands. Atmospheric Environment, 2015. 111: p. 202-212. https://doi.org/10.1016/j.atmosenv.2015.03.047
  24. Yun, S.J. and Y. Seo, Removal of bacteria and odor gas by an alumina support catalyst and negative air ions. Journal of aerosol science, 2013. 58: p. 33-40. https://doi.org/10.1016/j.jaerosci.2012.12.006
  25. Zzoli, M.a., Survey of the environmental health status of broiler farms in Babol city in 1392. Tabari Journal of Preventive Medicine, 1394.